Contact us : jacob@dpm.co.za
011 462 2204/5/6
Model 4004 and 5004
The Model 4004, 4 digit (-1999 to 9999) LED Load Cell Indicator is designed for mV inputs from loadcells, strain gauges and strain gauge pressure transmitters. The stable bridge excitation voltage includes sense feedback to compensate for line variations. The precision measuring front end circuit ensures high accuracy and stability. The digital filtering feature allows for stable displays in noisy systems. Options include programmable analog output, alarm setpoints up to four alarms, tare function, peak or valley hold, RS232/485 communications and more.
A feature of this programmable indicator / controller is the calibration method. The instrument can be pre-calibrated without load cell connections for zero and full scale values, and then on-site calibration can be done for deadweight offset and span calibration (single point test weight trim). The instrument meets European EMC directive 89/336/EEC and Low Voltage directive 73/23/EEC.
The Model 5004 is a 5½ digit (-199999 to 199999) version Load Cell Indicator. Digital filtering and programmable display increment allow for steady high count readings.
Features:
- DIN 48 x 96 enclosure
- -1999 to 9999 counts for Model 4004 ( -199999 to 199999 counts for Model 5004)
- Front keypad programmable
- Simple on-site calibration for deadweight and single point span calibration
- 14.2 mm height bright red LED display (optional green)
- 4-wire bipolar excitation
- Suitable for 1 mV/V, 2 mV/V, 3 mV/V and 10 mV/V bridges
- Low cost - high performance design
- Analog output option with programmable zero and span
- RS232 and RS485 bus communication option.
Options:
- 3001-P 2 alarm setpoints (solid state relays)
- 3001-M 2 alarm setpoints (electro-mechanical)
- 3002 RS 485 communications
- 3003 0 - 20 / 4 - 20 mA analog output
- 3004-P 1 alarm setpoint (solid state relay)
- 3004-M 1 alarm setpoint (electro-mechanical)
- 3006 Isolated outputs (order with 3002/3/7/13)
- 3007 0 - 5V / 0 - 10V analog output
- 3008 Galvanic isolated DC supply (12V / 24V)
- 3009 Parallel BCD output
- 3010 95-265V AC/DC power supply (4 loadcells)
- 3012 Peak or valley hold (min or max hold)
- 3013 RS 232 communications
- 3014 Tare function (local or remote)
- 3016 Loadcell booster (up to 6 loadcells)
- 3017-P 3 alarm setpoints (solid state relays)
- 3018-M 3 alarm setpoints (electro-mechanical)
- 3018-P 4 alarm setpoints (solid state relays)
- 3018-M 4 alarm setpoints (electro-mechanical)
- 3019 Green display
- 3020 Ultra bright red LED display
- 3022 Vertical bar graph display (4004 only)
- 3025 Key pad lock
- 3026 Display hold
Download Data Sheet DPM_4004_datasheet